Tracker: ECRs Priority: Highest Type: Bug
Found: -- Status: Closed Target: 10.1
OS: All Fixed: 10.1.0.0.14 PatchID: --
Description:
With the SimDB Integration, the XML unique_identifier is used to identify elements between the 2 different databases. Presently, we import the unique_identifier into the UniqueID item, but it is not created when a new element is created in OpenAmeos.

We should therefor add a function which creates the UniqueID item for every element which can be created in Ameos. It should only be created if the TI variable simdb_active is set.

Astrium uses Java's System.currentTimeMillis() for the unique_identifier.

Maybe the best solution here would be to add some kind of DefaultMappingValueFunc to the Item rules, but we're running out of time with this, so if this is too much effort (please advise), any other approach is ok, too.

Maybe, we can also find a solution which can also be used to rewrite the OMOS ChangeID implementation (see Redesign ChangeID implementation for performance improvement), I think the 3184 requirements are actually similar, just with a different callback.

Details:
Children (0)
Associations (0)
All (0)

Submitted Type Wiki Link Target Comment
Nothing found to display.

Submitted Type Wiki Link Source Comment
Nothing found to display.